Siemens SINAMICS G120 List Manual page 403

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

r9409
Number of parameters to be saved / Qty par to save
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of modified parameters and those that have still not be saved for this drive object.
Dependency:
Refer to: p0971
Notice:
Inherent to the system, the list of the parameters to be backed up is empty after the following actions:
- Download
- Warm restart
- Factory setting
In these cases, a new parameter backup must be initiated, which is then the starting point for the list of modified
parameters.
Note:
The modified parameters that still need to be saved are internally listed in r9410 ... r9419.
r9451[0...29]
Units changeover adapted parameters / Unit_chngov par
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the parameters whose parameter would have to be changed during a units changeover.
Dependency:
Refer to: F07088
r9463
Actual macro / Actual macro
Access level: 3
Can be changed: -
Unit group: -
Min
0
Description:
Displays the set valid macro.
Note:
A value of 0 is displayed if a parameter set by a macro is changed.
p9484
BICO interconnections search signal source / BICO S_src srch
Access level: 3
Can be changed: U, T
Unit group: -
Min
0
Description:
Sets the signal source (BO/CO parameter, BICO coded) to search in the signal sinks.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the
number (r9485) and the first index (r9486).
Dependency:
Refer to: r9485, r9486
r9485
BICO interconnections signal source search count / BICO S_src srchQty
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of BICO interconnections to the signal sink being searched for.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
999999
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
0
Data type: Unsigned16
Dyn. index: -
Func. diagram: -
Factory setting
-
403