For bit 13 = 1:
After the measurement has been completed, the system immediately goes into closed-loop speed controlled
operation.
Bit field:
Bit
01
02
03
04
11
12
13
Dependency:
Refer to: F07988
Note:
The following parameters are influenced for the individual optimization steps:
Bit 01: p0320, p0360, p0362 ... p0369
Bit 02: p0341, p0342
Bit 03: p1400.0, p1458, p1459, p1463, p1470, p1472, p1496
Bit 04: Dependent on p1960
p1960 = 1, 3: p1400.0, p1458, p1459, p1470, p1472, p1496
p1959[0...n]
Rotating measurement configuration / Rot meas config
PM250
Access level: 3
PM260
Can be changed: T
Unit group: -
Min
-
Description:
Sets the configuration of the rotating measurement.
Bit field:
Bit
01
02
03
04
11
Dependency:
Refer to: F07988
Note:
The following parameters are influenced for the individual optimization steps:
Bit 01: p0320, p0360, p0362 ... p0369
Bit 02: p0341, p0342
Bit 03: p1400.0, p1458, p1459, p1463, p1470, p1472, p1496
Bit 04: Dependent on p1960
p1960 = 1, 3: p1400.0, p1458, p1459, p1470, p1472, p1496
p1960
Rotating measurement selection / Rot meas sel
Access level: 3
Can be changed: T
Unit group: -
Min
0
Description:
Sets the rotating measurement.
The rotating measurement is carried out after the next switch-on command.
The setting possibilities of the parameter depend on the open-loop/closed-loop control mode (p1300).
p1300 < 20 (U/f open-loop control):
It is not possible to select rotating measurement or speed controller optimization.
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
Signal name
Saturation characteristic identification
Moment of inertia identification
Re-calculates the speed controller
parameters
Speed controller optimization (vibration test) Yes
Do not change the controller parameters
during the measurement
Measurement shortened
After measurement direct transition into
operation
Signal name
Saturation characteristic identification
Moment of inertia identification
Re-calculates the speed controller
parameters
Speed controller optimization (vibration test) Yes
Do not change the controller parameters
during the measurement
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: p0340 = 1
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
3
2 Parameters
2.2 List of parameters
0 signal
No
No
No
No
No
No
No
Data type: Unsigned16
Dyn. index: DDS, p0180
Func. diagram: -
Factory setting
0000 0000 0001 1110 bin
0 signal
No
No
No
No
No
Data type: Integer16
Dyn. index: -
Func. diagram: -
Factory setting
0
FP
-
-
-
-
-
-
-
FP
-
-
-
-
-
267