Mitsubishi Electric GT16 User Manual page 558

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

(2) Open settings
Item
Protocol
Open System
MELSOFT connection
POINT
POINT
POINT
When connecting to multiple GOTs and peripheral
devices
The number of protocols equivalent to that of the GOTs
and devices must be set.
22 - 48
22. ETHERNET CONNECTION
22.4 PLC Side Setting
Setting
Setting
(with GOT connected)
TCP
[Controller Setting] and [Ethernet] of GT
Designer3
(1) Controller setting
Item
GOT NET No.
GOT PLC No.
GOT IP Address
GOT Port No.
(Communication)
GOT Port No.
(Ethernet Download)
Default Gateway
Subnet Mask
Retry
Startup Time
Timeout Time
Delay Time
(2) Ethernet setting
Item
Host
N/W No.
PLC No.
Ethernet
Type
setting No.1
IP address
Port No.
Communication
*1
Set the value according to the IP address of the connected
PLC.
*2
Set the value according to the Port No. of the connected
PLC.
For details, refer to the following.
22.3.3 Ethernet setting
POINT
POINT
POINT
[Controller Setting] and [Ethernet] of GT Designer3
For [Controller Setting] and [Ethernet] of GT
Designer3, refer to the following.
22.3.1 Setting communication interface
(Communication settings)
Setting (Use default value.)
1
1
192.168.0.18
5019
5014
0.0.0.0
255.255.255.0
3times
3sec
3sec
0ms
Setting
*
1(Use default value)
2
FX (fixed)
*1
192.168.0.19
*2
5556
TCP (fixed)