Specify the number for [Network No.] and [Station
No.] same as the number assigned to the Ethernet
module.
When [QnUDE(H)] is set for [PLC type], the setting is
not required.
11.
Specify the IP address for [IP address] same as the
IP address assigned to the built-in Ethernet port
QCPU or Ethernet module.
12.
The screen returns to [Transfer Setup]. Click
to check if GX Works2 has been
Connection Test
connected to the QCPU (Q mode).
(4) Connecting the GOT and Ethernet adapter (NZ2GF-
ETB) in Ethernet connection, and connecting it to a
PLC in the CC-Link IE Field Network.
This section describes the settings of the GX Works2 in
the following case of system configuration.
POINT
POINT
POINT
Version of GX Works2
GX Works2 Version 1.34L or later is required to
execute the FA transparent function with using
Ethernet adapter (NZ2GF-ETB).
<GOT>
(Use default value for settings other than the following.)
Network No.
PC No.
IP address
Port No.
Communication
format
Ethernet
<Ethernet adapter unit>
(Use default value for settings other than the following.)
Ethernet setting
IP address
CC-Link IE Field Network setting
Network No.
Station No.
CC-Link IE Field Network
HUB
<CC-Link IE Field Network master/local unit>
(Use default value for settings other than the following.)
Network Type
: CC IE Field (Master station)
Network No.
: 1
PC No.
: 0
Total Stations
: 2
<CC-Link IE Field Network master/local unit>
(Use default value for settings other than the following.)
Network Type
: CC IE Field (Local station)
Network No.
: 1
PC No.
: 2
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting
:3
:1
:192.168.3.18
:5001
:UDP (fixed)
:192.168.3.30
:1
:1
31 - 45
28
29
30
31
32
33
34
35