50.3 Ethernet Connection

50.3.1 System configuration for connecting to FA-M3/M3V

FA-M3/M3V
PLC
Ethernet
interface
Series
module
*1
F3SP05
F3SP08
F3FP36
F3SP21
F3SP25
F3LE01-5T
F3SP35
F3LE11-0T
F3SP28
F3LE12-0T
F3SP38
F3SP53
F3SP58
F3SP59
F3SP76-7S
F3SP71-4S
F3LE11-0T
F3SP66
F3SP67
F3SP71-4N
-
F3SP76-7S
F3SP71-4S
*1
*2
*3
50 - 14
50. CONNECTION TO YOKOGAWA PLC
50.3 Ethernet Connection
PC link
FA-M3
module
Connection cable
Connection cable
*2
Cable model
• 10BASE-T
Shielded twisted pair cable
(STP) or unshielded twisted
pair cable (UTP) : Category 3,
4, and 5
• 100BASE-TX
Shielded twisted pair cable
(STP) : Category 5 and 5e
Product manufactured by YOKOGAWA Electric Corporation. For details of the product, contact Yokogawa Electric Corporation.
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standards.
Using the shielded twisted pair cable (STP) is recommended in the environment in which the performance against noise is
required.
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
Connector
conversion
box
Connector
conversion
External cable
box
GT16H-C30-42P(3m)
GT16H-CNB-42S
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-CNB-37S
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
GT16H-C30-42P(3m)
GT16H-CNB-42S
GT16H-C60-42P(6m)
GT16H-C100-42P(10m)
GT16H-C30-37PE(3m)
GT16H-CNB-37S
GT16H-C60-37PE(6m)
GT16H-C100-37PE(10m)
Communication driver
Ethernet(
GOT
External cable
Maximum
GOT
segment
Model
*3
length
100m
), Gateway
YOKOGAWA
Number of connectable
equipment
When PLC: GOT is N:1
The following shows
the number of PLCs for
1 GOT
TCP: 128 or less
UDP: 128 or less
When PLC: GOT is 1:N
The following shows
the number of GOTs
for 1 PLC
TCP: 8 or less
UDP: 128 or less
(recommended to 16
units or less)