52.4 GOT Side Settings

52.4.1 Setting communication
interface (Communication
settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: Azbil
• Controller Type: Set as follows.
<When connecting to DMC50 or AHC2001>
Azbil DMC50
<When connecting to a module other than the
above>
Azbil SDC/DMC
• I/F: Interface to be used
• Driver: Azbil SDC/DMC
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
52.4.2 Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
17.1.2 I/F communication setting
52.4.2 Communication detail settings
Item
Transmission
Speed
Data Bit
3.
Stop Bit
4.
Parity
Retry
Timeout Time
Host Address
Click!
*3,*4
Delay Time
Format
*2
*1
*2
*3
*4
52. CONNECTION TO AZBIL CONTROL EQUIPMENT
Description
Set this item when change the transmission
speed used for communication with the
connected equipment.
(Default: 9600bps)
Set this item when change the data length
used for communication with the connected
equipment.
(Default: 8bits)
Specify the stop bit length for communications.
(Default: 1bit)
Specify whether or not to perform a parity
check, and how it is performed during
communication.
(Default: Even)
Set the number of retries to be performed
when a communication error occurs.
(Default: 0time)
Set the time period for a communication to
time out.
(Default: 3sec)
Specify the host address (station No. of the
GOT to which the temperature controller is
connected) in the connected network.
(Default: 1)
Set this item to adjust the transmission timing
of the communication request from the
GOT.*1
(Default: 1ms)
Select the communication format.
(Default: 1)
format 1: only continuous access
format 2: continuous and random access
Do not specify "0".
Format is ignored when connecting to DMC50.
Host Address is ignored when connecting to DMC10 or SDC.
Host Address is valid when connecting to DMC50.
Devices to be the target of Host Address setting differ
depending on the system configuration.
• When connecting to the temperature controller via COM module
Specify the station No. of the COM module.
• When connecting to the temperature controller directly
Specify the station No. of the temperature controller.
52.4 GOT Side Settings
52
Range
53
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
7bits/8bits
54
1bit/2bits
None
Even
Odd
0 to 5times
55
3 to 30sec
1 to 15
0 to 300ms
56
1/2
57
58
59
52 - 17