42.4 GOT Side Settings

42.4.1
Setting communication interface
(Communication settings)
Set the channel of the equipment connected to the GOT.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: TOSHIBA MACHINE
• Controller Type: TOSHIBA MACHINE TCmini
• I/F: Interface to be used
• Driver: TOSHIBA MACHINE TCmini
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

42.4.2 Communication detail settings

Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
17.1.2 I/F communication setting
42.4.2 Communication detail settings
Make the settings according to the usage environment.
Item
Transmission
Speed
3.
Data Bit
4.
Stop Bit
Parity
Click!
Retry
Timeout Time
Host Address
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
42. CONNECTION TO TOSHIBA MACHINE PLC
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 9600bps)
Set this item when change the data
length used for communication with
the connected equipment.
(Default: 8bit)
Specify the stop bit length for
communications.
(Default: 2bits)
Specify whether or not to perform a
parity check, and how it is
performed during communication.
(Default: None)
Set the number of retries to be
performed when a communication
error occurs.
(Default: 3times)
Set the time period for a
communication to time out.
(Default: 3sec)
Specify the host address (station
No. of the GOT to which the PLC is
connected) in the connected
network.
(Default: 0)
Set this item to adjust the
transmission timing of the
communication request from the
GOT.
(Default: 0ms)
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following.
12. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
42.4 GOT Side Settings
36
37
Range
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
38
7bits/8bits
1bit/2bits
None
Even
39
Odd
0 to 5times
3 to 30sec
40
0 to 63
0 to 300(ms)
41
42
43
42 - 3