Mitsubishi Electric GT16 User Manual page 680

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

(3) When connecting the GOT and PLC in Ethernet communication
The following shows the software and the accessible PLC CPUs.
RCPU
Motion controller CPU
(MELSEC iQ-R Series)
C Controller module (MELSEC iQ-R Series)
FX5U, FX5UC
*1
QCPU (Q mode)
, C Controller module (Q Series)
LCPU
FXCPU
QCPU (A mode), QnA/ACPU
Motion controller CPU (Q Series)
CNC CPU (Q173NCCPU)
Robot controller (CRnQ-700, CRnD-700)
MELSERVO(MR-J3-B)
MELSERVO(MR-J4-B)
*1
Only QCPU can be connected. To connect to QnA/ACPU, connect via QCPU.
*2
GX Developer Version 8.78G or later is required to use the FA transparent function.
*3
GX Works2 Version 1.10L or later is required to use the FA transparent function.
*4
MT Developer2 Version 1.08J or later is required to use the FA transparent function.
*5
NC Configurator Version A1 or later is required to use the FA transparent function.
*6
MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*7
GX Developer Version 8.88S or later is required to use the FA transparent function.
*8
GX Works2 Version 1.11M or later is required to use the FA transparent function.
*9
MT Works2 Version 1.12N or later is required to connect with Q17nDCPU-S1.
*10
MELSOFT Navigator Version 1.07H or later is required to use the FA transparent function.
*11
MX Component Version 4.03D or later is required to use the FA transparent function.
*12
Use MX Component Version 3.14Q or later for MX Sheet.
*13
GX Works2 Version 1.34L or later is required to execute the FA transparent function with using CC-Link IE Field Network Ethernet
adapter module (NZ2GF-ETB).
C controller module (Q Series) does not support CC-Link IE Field Network.
*14
CPU Module Logging Configuration Tool Version 1.04E or later is required to use the FA transparent function.
*15
RT ToolBox2 Version 1.7 or later is required to use the FA transparent function.
*16
MR Configurator2 Version 1.09K or later is required to use the FA transparent function.
*17
A motion controller is required between the GOT and PLC in Ethernet connection.
*18
Setting/Monitoring tool for C Controller module Version 4.00A or later is required to use the FA transparent function.
*19
GX Works2 Version 1.98C or later is required to use the FA transparent function.
*20
MT Works2 Version 1.100E or later is required to use the FA transparent function.
*21
MX Component Version 4.06G or later is required to use the FA transparent function.
*22
Use MX Component Version 4.06G or later for MX Sheet.
*23
GX Works3 Version 1.005F or later is required to use the FA transparent function.
*24
MX Component Version 4.11M or later is required to use the FA transparent function.
*25
MX Sheet, please use the MX Component (Version 4.11M or later).
31 - 4
31. FA TRANSPARENT FUNCTION
31.2 Compatible Software
PLC CPU
*1
*17
*17
*21
GX Works3, MX Component
, MX Sheet
*20
*21
MT Works2
, MX Component
CW Configurator
*23
*24
GX Works3
, MX Component
*6
MELSOFT Navigator
*2
*3*13
GX Developer
, GX Works2
*11
*12
MX Component
, MX Sheet
Setting/Monitoring tool for C Controller module
*10
MELSOFT Navigator
*7
*8
GX Developer
, GX Works2
GX LogViewer
*11
*12
MX Component
, MX Sheet
, CPU Module Logging Configuration Tool
*19
GX Works2
*2
GX Developer
*11
*12
MX Component
, MX Sheet
*6
MELSOFT Navigator
*4*9
MT Works2
*5
NC Configurator
*15
RT ToolBox2
MR Configurator2
*16
MR Configurator2
Software
*22
*22
, MX Sheet
*25
, MX Sheet
*18
*14

Advertisement

Table of Contents
loading

Table of Contents