Connecting the GOT and PLC in direct
connection (when connecting to FXCPU)
1.
Click [Online]
[Read from PLC] in GX Developer.
2.
Set the [PLC Series] to [FXCPU].
3.
The [Transfer Setup] is displayed.
4.
Set the [Transfer Setup]:
PC side I/F
: Serial
PLC side I/F
: PLC module
Other station
: No specification
5.
Double-click [Serial] of the PC side I/F to display [PC
side I/F Serial setting].
6.
Check the following for [PC side I/F Serial setting].
When connecting the GOT and PC with USB
Mark the [USB(GOT transparent mode)] checkbox.
7.
The screen returns to the [Transfer Setup]. Click the
[Connection Test] to check if GX Developer has been
connected to the FXCPU.
POINT
POINT
POINT
How to operate GX Developer
For the GX Developer operation method, refer to the
following manual.
GX Developer Version
31. FA TRANSPARENT FUNCTION
31.6 Personal Computer Side Setting