*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is
required.
*2
A straight cable is available.
When connecting the GOT and CPU directly with Ethernet cable, a cross cable is also available.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of Built-in Ethernet port QCPU, refer to the following manual.
*5
Select [QnUD(P)V/QnUDEH] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*6
For the system configuration of Built-in Ethernet port LCPU, refer to the following manual.
*7
Select [LCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*8
Select [RCPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*9
For the system configuration of Built-in Ethernet port RCPU, refer to the following manual.
*10
Select [FX5CPU] for [Controller Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*11
For the system configuration of MELSEC iQ-F series, refer to the following manual.
22 - 10
22. ETHERNET CONNECTION
22.2 System Configuration
QCPU User's Manual (Hardware Design, Maintenance and Inspection)
22.3.3 Ethernet setting
MELSEC-L CPU User's Manual (Built-In Ethernet Function)
22.3.3 Ethernet setting
22.3.3 Ethernet setting
Manuals of MELSEC iQ-R Series
22.3.3 Ethernet setting
MELSEC iQ-F User's Manual