Mitsubishi Electric GT16 User Manual page 985

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

(2) Setting for the built-in MP2300S Ethernet and 218IF-
02
Make the parameter settings with a peripheral tool.
Item
IP Address
Transmission
Subnet Mask
parameter
Gateway IP Address
setting
Device Name
Engineering Port
Transmission
parameter
Response Time
detailed setting
Count of Retry
(Number of Retries)
Connection Number
Local Port
*1
Node IP Address
Message
*1
communication
Node Port
of connection
parameter
Connection Type
setting
Protocol Type
Code
Node Name
*1
Set the same the Node IP Address (Remote Station's IP
Address) and the Node Port (Remote Station's Port Number)
as the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side.
For the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side, refer to the following.
49.3.2 ■ Ethernet setting
(3) Setting for 218TXB
(a) DIP switch (SW2) setting
Set all the "unused" switches to off. When the
"unused" switches are on, the PLC does not
operate properly. In addition, when the PLC is
operated with the TEST switch on, the module
shifts to the self-check mode and communication is
disabled. To start communication, turn the TEST
switch to off.
SW2
N/O
10/100
F/H
INIT
TEST
ON
OFF
Set value
Range
PLC side IP
[ ].[ ].[ ].[ ]
address
[ ].[ ].[ ].[ ]
PLC side
setting
[ ].[ ].[ ].[ ]
Up to 16 one-byte
Arbitrary
characters
For a connection
256 to 65535
with software
MPE720
0
Not required for
communication
0
with GOT
• Range of built
in MP2300S
Ethernet: 1 to 4
1
• Range of
218IF-02: 1 to
20
10500
256 to 65534
IP address
[ ].[ ].[ ].[ ]
of GOT
Port No.
[ ]
of GOT
UDP
TCP/UDP
(recommended)
Extended
MEMOBUS,
Extended
MEMOBUS,
MEMOBUS
MELSEC,
None,
MODBUS/TCP
BIN
RTU, BIN, ACII
Up to 32 one-byte
characters
Arbitrary
(16 two-byte
characters)
Display
Name
Position
ON
Mode
N/O
selection
OFF
-
Unused
ON
Transmission
10/100
speed
OFF
ON
Transmission
F/H
mode
OFF
ON
engineering port No.
INIT
Initial startup
OFF
Self check (Self check
ON
is conducted when the
TEST
TEST
module is started with
OFF
the TEST switch on.)
(b) Parameter settings
Make the parameter settings with a peripheral tool.
Item
IP Address
Transmission
Subnet Mask
parameter
Gateway IP Address
setting
Device Name
Engineering Port
Transmission
parameter
Response Time
detailed setting
Count of Retry
(Number of Retries)
Connection Number
Local Port
*1
Node IP Address
Message
*1
Node Port
communication
of connection
Connection Type
parameter
setting
Protocol Type
Code
Node Name
*1
Set the same the Node IP Address (Remote Station's IP
Address) and the Node Port (Remote Station's Port Number)
as the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side.
For the Local IP Address and the Local Port (Local Station's
Port Number) on the GOT side, refer to the following.
49.3.2 ■ Ethernet setting
49. CONNECTION TO YASKAWA PLC
49.3 Ethernet Connection
Operation
Set value
Extended mode
(13 channels and
ON
Max. 1024 words)
(extended
Basic mode
mode)
(10 channels and
Max. 512 words)
OFF
10Mbps
OFF
(100Mbps)
100Mbps
Full duplex mode
OFF
communication
(Half-duplex
Half duplex mode
mode)
communication
Startup with the
default IP address
and the default
OFF
Startup with the IP
address and the
engineering port No
set in CP-717.
OFF
Set value
Range
PLC side
[ ].[ ].[ ].[ ]
IP address
[ ].[ ].[ ].[ ]
PLC side setting
[ ].[ ].[ ].[ ]
Up to 16 one-byte
Arbitrary
characters
For a connection
256 to 65535
with software
MPE720
0
Not required for
communication
0
with GOT
• Range of built
in MP2300S
Ethernet: 1 to 4
1
• Range of 218IF-
02: 1 to 20
10500
256 to 65534
IP address
[ ].[ ].[ ].[ ]
of GOT
[ ]
Port No. of GOT
UDP
TCP/UDP
(recommended)
Extended
MEMOBUS,
Extended
MEMOBUS,
MEMOBUS
MELSEC, None,
MODBUS/TCP
BIN
RTU, BIN, ACII
Up to 32 one-byte
characters
Arbitrary
(16 two-byte
characters)
49 - 15
44
45
46
47
48
49
50
51