Mitsubishi Electric GT16 User Manual page 825

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

RS422 connection diagram 3)
Connector conversion
box side
RDA
2
RDB
7
SDA
1
SDB
6
RSA
3
RSB
8
CSA
4
CSB
9
SG
5
FG
-
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 150
PLC at a terminal station.
RS422 connection diagram 5)
Connector conversion
box side
RDA
2
RDB
7
SDA
1
SDB
6
RSA
3
RSB
8
CSA
4
CSB
9
SG
5
FG
-
*1
Connect FG grounding to the appropriate part of a cable shield line.
*2
Connect a terminating resistor (approximately 150
When the number of links exceeds 30, use a transmission line conversion unit D-01CV per 30 links.
For details, refer to the following manual.
KOYO EI PLC side
+TXD
14
-TXD
15
+RXD
17
-RXD
16
-
1 to 6
+RTS
8
-RTS
9
-
18 to 21
LG
7
+RTS
10
-RTS
11
+CTS
12
-CTS
13
+TXD
22
-TXD
23
-RXD
24
* 1
* 2
+RXD
25
) to the
KOYO EI PLC side
+TXD
14
-TXD
16
+RXD
9
-RXD
10
-
1 to 6
-
8
-
12
-
13
SG
7
-
15
-
17
-RTS
18
+RTS
19
-
20 to 22
-CTS
23
+CTS
11
-
* 1
24, 25
KOYO EI PLC user's Manual
RS422 connection diagram 4)
Connector conversion
box side
RDA
2
RDB
7
SDA
1
SDB
6
RSA
3
RSB
8
CSA
4
CSB
9
SG
5
FG
-
*1
Connect FG grounding to the appropriate part of a cable
shield line.
*2
Connect a terminating resistor (approximately 100 to 500
to the PLC to be a terminal.
KOYO EI PLC side
+TXD
14
-TXD
16
+RXD
9
-RXD
10
-
1 to 6
* 2
-
8
-
12
-
13
SG
7
-
15
-
17
-RTS
18
+RTS
19
-
20 to 22
-CTS
23
+CTS
11
-
* 1
24, 25
) to the PLC at a terminal station.
36. CONNECTION TO KOYO EI PLC
36.3 Connection Diagram
KOYO EI PLC side
+TXD
9
-TXD
10
+RXD
13
-RXD
6
5V
1
* 2
-
2 to 5
0V
8
0V
7
+RTS
11
-RTS
12
+CTS
14
* 1
-CTS
15
36 - 9
36
37
38
39
)
40
41
42
43

Advertisement

Table of Contents
loading

Table of Contents