25.4 GOT Side Settings

25.4.1
Setting communication interface
(Communication settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: Mitsubishi
• Controller Type: Set according to the Controller
Type to be connected.
• I/F: Interface to be used
• Driver: MELSERVO-J4, J3, J2S/M, JE
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

25.4.2 Communication detail settings

Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
17.1.2 I/F communication setting
25.4.2 Communication detail settings
Make the settings according to the usage environment.
Transmission
Speed
3.
Data Bit
4.
Stop Bit
Parity
Retry
Click!
Timeout Time
Host address
Delay Time
Station No.
Selection
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
25. SERVO AMPLIFIER CONNECTION
Item
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 9600bps)
Set this item when change the data
length used for communication with
the connected equipment.
(Default: 8bit)
Specify the stop bit length for
communications. (Default: 1bit)
Specify whether or not to perform a
parity check, and how it is
performed during communication.
(Default: Even)
Set the number of retries to be
performed when a communication
error occurs.
(Default: 3times)
Set the time period for a
communication to time out.
(Default: 3sec)
Specify the station number of the
servo amplifier in the system
configuration.
(Default: 0)
Set this item to adjust the
transmission timing of the
communication request from the
GOT.
(Default: 0ms)
Specify whether to use the station
No. during communication.
If [Yes] is selected, the station No.
is fixed to "0." (Default: Yes)
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For the details on the Utility, refer to the following
manual.
12. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
25.4 GOT Side Settings
20
21
Range
9600bps,
19200bps,
38400bps,
57600bps
115200bps
8bit (fixed)
22
1bit (fixed)
Even (fixed)
23
0 to 5times
3 to 30sec
0 to 31
24
0 to 300(ms)
Yes or No
25
26
27
25 - 9