Mitsubishi Electric GT16 User Manual page 94

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

• Operation setting
Store the rotary switch value into the station No. switching device (GD500).
The station No. switching device value is an unsigned 16bits data where the upper 8bits are the network No. and
the lower 8bits are the PC No.
(1) Set [Data Set 16bit] to [Action] and [Unsigned BIN] to [Data] in the Action tab.
(2) Set a station No. switching device [GD500] to [Device].
(3) To set the rotary switch value of the connector conversion box, tick the check box of [Indirect] and click the [...]
button to display the Select CH No. window.
(4) Click MODBUS in the Select CH No. screen to open the device setting window of MODBUS.
(5) Input "3-00001" to Device. Select [Host] for Network. Click the [OK] button when settings are completed.
"3-00001" is a fixed register to access to the rotary switch of the connector conversion box by the MODBUS
communication.
(6) Check that [@2 300001] is displayed at [Device]-[Indirect] in the Action tab.
6 - 22
6. OPTION
6.7 Connector Conversion Box

Advertisement