Connecting To D0-Dcm - Mitsubishi Electric GT16 User Manual

Got1000 series
Hide thumbs Also See for GT16:
Table of Contents

Advertisement

36.5.7 Connecting to D0-DCM

Communication settings
Write the following communication settings to the
specified register using the programmer.For details of
the register, refer to the following manual.
KOYO EI PLC user's Manual
Item
Transmission mode
Protocol
Station No.
*1
Transmission speed
Parity
RTS On Delay Time
(Only communication port 2)
RTS Off Delay Time
(Only communication port 2)
Timeout
(Only communication port 2)
485 mode selection
(Only communication port 2)
Data bit
(Only communication port 2)
Stop bit
(Only communication port 2)
The timeout between
characters
(Only communication port 2)
The completion of a setting
Reset timeout
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
36.5.8 Connecting to D2-DCM
Communication settings
Make the following settings using the programmer.
Item
Station No.
1 to 90
*1
9600bps, 19200bps, 38400bps
Transmission speed
Data bit
8bits (Fixed)
Stop bit
1bit (Fixed)
Parity
NONE, ODD
Self-diagnostic mode
OFF
Response delay time
0ms
Peer to Peer
OFF
Master/Slave
Slave
Timeout
Enable
Transmission mode
HEX
MODBUS
OFF
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
36 - 16
36. CONNECTION TO KOYO EI PLC
36.5 PLC Side Setting
Set value
HEX
DirectNet
1 to 90
9600bps, 19200bps, 38400bps,
57600bps, 115200bps
NONE, ODD,
EVEN (Only communication port 2)
0ms
0ms
800ms/960ms/1200ms/1600ms/
4000ms/8000ms/16000ms/40000ms
RS232RS422/485 4 line type
8bits, 7bits
1bit, 2bits
0 to 9999ms
Default use,A preset value is effective
Invalid,Effective
Set value
36.5.9 Station NO. setting
Set each station number so that no station number
overlaps.
The station number can be set without regard to the cable
connection order. There is no problem even if station
numbers are not consecutive.
Station No.3
GOT
The example of a Station No. setting
(1) Direct specification
Specify the station No. of the PLC to be changed when
setting device.
Specification range
1 to 90
Station No.1
Station No.15