50.2.5 GOT side settings

Setting communication interface
(Communication settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
[Controller Setting] from the
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: YOKOGAWA
• Controller Type: Set either of the followings.
• FA500/FA-M3 series
• STARDOM/FA-M3 series
• I/F: Interface to be used
• Driver: YOKOGAWAFA500/FA-M3/STARDOM
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.
50.2.5■Communication detail settings
Click the [OK] button when settings are completed.
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
17.1.2 I/F communication setting
Communication detail settings
Make the settings according to the usage environment.
Item
Transmission
Speed
3.
Data Bit
Stop Bit
4.
Parity
Sum Check
Click!
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
(1) Communication interface setting by the Utility
(2) Precedence in communication settings
50. CONNECTION TO YOKOGAWA PLC
Description
Set this item when change the
transmission speed used for
communication with the connected
equipment.
(Default: 9600bps)
Set this item when change the data
length used for communication with
the connected equipment.
(Default: 8bits)
Specify the stop bit length for
communications.
(Default: 1bit)
Specify whether or not to perform a
parity check, and how it is
performed during communication.
(Default: No)
Set whether or not to perform a
sum check during communication.
(Default: Yes)
Set the number of retries to be
performed when a communication
timeout occurs.
When receiving no response after
retries, the communication times
out.
(Default: 0time)
Set the time period for a
communication to time out.
(Default: 3sec)
Set this item to adjust the
transmission timing of the
communication request from the
GOT.
(Default: 0ms)
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following.
12. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
50.2 Serial Connection
44
Range
4800bps,
9600bps,
19200bps,
45
38400bps,
57600bps,
115200bps
7bits/8bits
1bit/2bits
46
None
Even
Odd
Yes or No
47
0 to 5times
3 to 30sec
48
0 to 30
(
10 ms)
49
50
51
50 - 7