Ethernet setting
Item
Description
The host is displayed. (The host is
Host
indicated with an asterisk (*).))
Set the network No. of the
N/W No.
connected Ethernet module.
(Default: blank)
Set the station No. of the
*1
connected Ethernet module.
PLC No.
(Default: blank)
Type
OMRON (fixed)
Set the IP address of the
IP address
connected Ethernet module.
(Default: blank)
Set the port No. of the connected
Port No.
Ethernet module.
(Default: 9600)
Communication
Select a communication protocol.
format
(Default: UDP)
*1
Each of [GOT PLC No.] set in the communication detail
setting and [PLC No.] set in the Ethernet setting must be set
to different station numbers.
41.3.2 ■ Communication detail settings
POINT
POINT
POINT
(1) Communication interface setting by the Utility
The communication interface setting can be
changed on the Utility's [Communication setting]
after writing [Communication Settings] of project
data.
For details on the Utility, refer to the following.
12. COMMUNICATION INTERFACE SETTING
(COMMUNICATION SETTING)
(2) Precedence in communication settings
When settings are made by GT Designer3 or the
Utility, the latest setting is effective.
arbitrary

41.3.3 PLC side setting

Setting of operation mode switch and station
address switch
Set value
1 to 127
1 to 254
TOSHIBA (fixed)
PLC side IP
address
(1) Station address setting switch
The station address setting switches are hexadecimal
256 to 65534
rotary switches that determine the station address on
the Ethernet network.
UDP(fixed)
Set the station address (1 to 254) that has been
assigned upon system configuration in a HEX code.
Assign an address with a different value to each of the
nodes in the system.
name
STN-H
STN-L
(2) Operation mode setting switch
Description
Operation
mode
IP address
type
41. CONNECTION TO TOSHIBA PLC
Station address
setting switch
Operation mode
setting switch
Description
Upper address: 0 to F (Hex)
Lower address: 0 to F (Hex)
Settings
1
2
Nomal
OFF
OFF
ON
OFF
For maintenance
OFF
ON
Class B
*1
172.16.64.XX
Reserved
Class C
*2
192.168.0.XX
*3
Tool setting
*1
XX indicates the value of the station address setting
switches.
Subnet mask : 255.255.192.0
*2
XX indicates the value of the station address setting
switches.
Subnet mask : 255.255.255.0
*3
It can be set freely from the engineering tool, and the value
has precedence over the value of the station address setting
switches.
41.3 Ethernet Connection
36
37
38
39
40
Range
01 to FE (Hex)
41
Switch No.
3
6
7
8
OFF
OFF
OFF
OFF
OFF
OFF
42
OFF
ON
OFF
OFF
OFF
ON
ON
ON
ON
43
41 - 9