36.5.2 Connecting to SU-5M/6M

Communication settings
Make the following settings using the programmer
system parameter setting.
Item
Protocol
CCM
Response delay time
0ms
800ms/960ms/1200ms/1600ms/4000ms/
Timeout Time
8000ms/16000ms/40000ms
Station No.
1 to 90
Transmission mode
HEX
Stop bit
1bit, 2bits
Data bit
8bits (Fixed)
Parity
NONE, ODD, EVEN
*1
9600bps, 19200bps, 38400bps
Transmission speed
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
36.5.3 Connecting to DirectLOGIC 05
series or DirectLOGIC 06
series
Communication settings
Make the following settings using the programmer
system parameter setting.
Item
Protocol
CCM NET (DirectNET)
Timeout
780ms or more
RTS On Delay Time
0ms
RTS Off Delay Time
0ms
Station No.
1 to 90
*2
9600bps, 19200bps, 38400bps
Transmission speed
Stop bit
1bit, 2bits
Parity
NONE, ODD, EVEN
Communication format
HEX
*1
To use a PLC with multidrop, set the "RTS on delay time" to
5ms or more and the "RTS off delay time" to 2ms or more.
*2
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
36 - 14
36. CONNECTION TO KOYO EI PLC
36.5 PLC Side Setting
Set value
Set value
*1
*1
36.5.4 Connecting to DirectLOGIC
205 series
Communication settings
Make the following settings using the programmer
system parameter setting.
Item
Protocol
CCM NET (DirectNET)
Station No.
1 to 90
*1
9600bps, 19200bps, 38400bps
Transmission speed
Data bit
8bits (Fixed)
Stop bit
1bit (Fixed)
Parity
NONE, ODD
Self-diagnostic mode
OFF
Response delay time
0ms
Peer to Peer
OFF
Master/Slave
Slave
Timeout
Enable
Transmission mode
HEX
MODBUS
OFF
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
36.5.5 Connecting to PZ Series
Communication settings
Make the following settings using the programmer
system parameter setting.
Item
Protocol
CCM NET
800ms/960ms/1200ms/1600ms/4000ms/
Timeout
8000ms/16000ms/40000ms
Response delay time
0ms
Station No.
1 to 90
Communication format
HEX
*1
9600bps, 19200bps, 38400bps
Transmission speed
Stop bit
1bit
Parity
NONE, ODD
*1
Indicates only the transmission speeds that can be set on
the GOT side.
Set the same transmission speed of the GOT.
Set value
Set value