Configuration Save & Restore; Write Startup-Config - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart[{factory}]
The parameters have the following meaning:
Parameter
factory
If you do not select any parameters from the parameter list, the system restarts with the
current configuration.
Result
The device is restarted with the selected settings.
3.4
Configuration Save & Restore
This section describes commands for displaying, saving and restoring configuration settings.
3.4.1

write startup-config

Description
With this command, you save the changes to the configuration in the configuration file.
The use of this command is required in the Trial mode. It can also be used in "auto save
mode".
Requirement
● The Trial mode is activated.
● You are in the Privileged EXEC mode.
The command prompt is:
*cli(...)#
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
Restarts the system with the factory configuration settings
Configuration
3.4 Configuration Save & Restore
113