No Smtp-Server - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Network protocols
7.8 SMTP Client
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-server { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr> } <receiver
mail-address>
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
ipv6
ip6_addr
receiver mail-
address
For information on addresses and interfaces, refer to the section "Addresses and interface
names (Page 39)".
Result
An entry for the SMTP server is configured.
Further notes
You delete an SMTP server entry with the
7.8.2.2

no smtp-server

Description
With this command, you delete an SMTP server entry.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
370
Description
Keyword for an IPv4 address
IPv4 address of the SMTP server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
IPv6 address of the SMTP server
Name of the recipient
no smtp-server
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Note on the range if values
-
Enter a valid IPv4 unicast ad-
dress.
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
Maximum of 100 characters
command.
Configuration Manual, 11/2015, C79000-G8976-C252-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents