No Poe Pse Maximumpower - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command with the following parameters:
poe pse <integer(1-4)> MaximumPower <integer(1-90)>
The parameters have the following meaning:
Parameter
integer
integer
Result
The value for the maximum power is configured.
Further notes
You delete the value for the parameter "Maximum Power" with the
command.
3.5.2.2

no poe pse MaximumPower

Description
With this command, you delete the value for the "Maximum Power" parameter.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no poe pse <integer(1-4)> MaximumPower
The parameters have the following meaning:
Parameter
integer
Result
The value for the maximum power is deleted.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
Number of the PSE
Value for the maximum power
Description
Number of the PSE
Configuration
3.5 PoE
Range of values / note
1 ... 4
1 ... 90
no poe pse MaximumPower
Range of values / note
1 ... 4
121