Fmp Rx-Power - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Diagnostics
12.2 FMP
12.2.2.4

fmp rx-power

Description
With this command, you specify the limit values for monitoring the received power per port.
Requirement
You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
rmon rx-power [req]<1/10 dBm> [dem]<1/10 dBm>
The parameters have the following meaning:
Parameter
req
dem
Result
The limits for monitoring the received power are defined.
Further notes
You enable this function with the
You disable this function with the
You display the status of this function and other information with the
show fmp limit
You define the limit values for the power loss with the command
784
Description
Specify the value at which you are informed of
the deterioration of the received power by a
message of the severity level "Warning"
Specify the value at which you are informed of
the deterioration of the received power by a
message of the severity level "Critical"
commands.
Range of values / note
0 ... -40 dB
The default value depends on the rele-
vant pluggable transceiver.
0 ... -40 dB
The default value depends on the rele-
vant pluggable transceiver.
command.
fmp
command.
no fmp
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
and
show fmp stauts
.
fmp power-loss

Hide quick links: