Commands In The Ptp Transparent Clock Configuration Mode; Delay-Mechanism - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Result
You are in the PTP Transparent Clock configuration mode.
The command prompt is as follows:
cli(config-ptp-tc)#
5.4.3

Commands in the PTP Transparent Clock configuration mode

This section describes commands that you can call up in the PTP Transparent Clock
configuration mode.
In the Global configuration mode, enter the
to change to this mode.
● If you exit the PTP Transparent Clock configuration mode with the
return to the Global configuration mode.
● If you exit the PTP Transparent Clock configuration mode with the
return to the Privileged EXEC mode.
5.4.3.1

delay-mechanism

Description
With this command, you specify which correction mechanism the Precision Time Protocol
uses.
Requirement
You are in the PTP Transparent Clock configuration mode.
The command prompt is as follows:
cli(config-ptp-tc)#
Syntax
Call up the command with the following parameters:
delay-mechanism { end-to-end | peer-to-peer }
The parameter has the following meaning:
Parameter
end-to-end
peer-to-peer
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
The device operates as an end-to-end trans-
parent clock.
The device operates as a peer-to-peer trans-
parent clock.
ptp transparent-clock configuration
Range of values / note
With end-to-end synchroniza-
tion with more than 2 slaves,
freak values > 100 ns can oc-
cur in the offset.
-
System time
5.4 PTP Client
command
command, you
exit
command, you
end
165