No Rmon Alarm - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Note
Conditions for working with alarms
The events assigned to the alarms are configured.
The Remote monitoring function is started with the
Result
The alarm for monitoring a MIB variable is configured.
Further notes
You delete an alarm with the
You display the list of configured RMON alarms with the
12.5.2.4

no rmon alarm

Description
With this command, you delete an alarm for monitoring a MIB variable.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no rmon alarm <number (1-52)>
The parameter has the following meaning:
Parameter
number
Result
The entry for monitoring a MIB variable is deleted.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
command.
no rmon alarm
Description
Number of the alarm to be deleted
command.
rmon
show rmon alarms
Range of values / note
1 ... 52
Diagnostics
12.5 RMON
command.
811