Layer 3 functions
9.3 OSPFv3 (IPv6)
Syntax
Call up the command with the following parameters:
show ipv6 ospf
database
prefix|link|nssa
}]
The parameters have the following meaning:
Parameters
area
AreaID
router
network
as-external
inter-prefix
inter-router
intra-prefix
link
nssa
detail
HEX
If you do not select any parameters from the parameter list, the entire content od the
database is shown.
Result
The information is displayed.
500
[area <AreaID>]
[ {
router|network|as-external|inter-prefix|inter-router|intra-
} ]
[{
detail|HEX
Description
Keyword for the area ID
Area ID
only shows information of the LSA type "Router" (type
2001)
only shows information of the LSA type "Network" (type
2002)
only shows information of the LSA type "AS External" (type
4005)
only shows information of the LSA type "inter-area prefix"
(type 2003)
only shows information of the LSA type "inter-area router"
(type 2004)
only shows information of the LSA type "intra-area prefix l"
(type 2009)
only shows information of the LSA type "link" (type 2008)
only shows information of the LSA type "type-7 LSA" (type
2007)
shows Information in detail
shows Information in hexadecimal format