System time
5.4 PTP Client
5.4.2.3

ptp time diff

Description
With this command, you set the time zone for the Precision Time Protocol.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ptp time diff <(+/-hh:mm)>
The parameter has the following meaning:
Parameter
+/-hh:mm
Result
The time zone for the Precision Time Protocol is specified.
5.4.2.4

ptp transparent-clock configuration

Description
With this command you change to the PT Transparent Clock configuration mode.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameter assignment:
ptp transparent-clock configuration
164
Description
The value for the time difference.
Range of values / note
Hours and minutes specified in
the format
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
+/-HH:MM