Network structures
6.3 Spanning Tree
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree mst hello-time <seconds(1-2)>
The parameter has the following meaning:
Parameter
seconds
Result
The setting for the hello time is configured.
Further notes
You can reset the setting for the hello time to the default with the
hello-time
You display this setting and other information with the commands that start with
spanning tree ...
6.3.5.19

no spanning-tree mst hello-time

Description
With this command, you reset the hello time after which the bridge sends its configuration
BPDUs to the default value.
The default value is 2 seconds.
Requirement
You are in the interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree mst hello-time
248
Description
Time after which the bridge sends its
configuration frames (BPDUs)
command.
.
Range of values / note
1 ... 2
Default: 2
no spanning-tree mst