Layer 3 functions
9.6 RIPv2 (IPv4)
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#
Syntax
Call up the command with the following parameters:
no distribute-list route-map <name(20)> {in | out}
The parameters have the following meaning:
Parameter
name
in
out
Result
The filtering is disabled.
9.6.3.8

network

Description
This command enables the RIP protocol for an IP interface.
Requirement
You are in the RIPv2 Router configuration mode.
The command prompt is as follows:
cli(config-rip)#
Syntax
Call up the command with the following parameters:
network <ip-address>
The parameter has the following meaning:
Parameter
ip-address
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
598
Description
Name of the routing table.
The filtering for incoming routing infor-
mation is disabled.
The filtering for outgoing routing infor-
mation is disabled.
Description
The IP address for which RIP will be
enabled.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
Maximum of 20 characters.
-
-
Range of values / note
Specify a valid IP address.
Configuration Manual, 11/2015, C79000-G8976-C252-10