3.1.12.11

username

Description
With this command, you change the password of the factory set default users "
"
admin
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
username {user|admin} password <passwd>
The parameters have the following meaning:
Parameter
user
admin
password
passwd
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
".
Description
User name of the default user with
read access to the configuration
data.
User name of the default user with
read and write access to the con-
figuration data.
Keyword for a password
Value for the password
Range of values / note
-
-
-
Enter the password.
The password must meet the following
password policies:
Password length: at least 8 characters
at least 1 uppercase letter
at least 1 special character
at least 1 number
Configuration