Poe Pse Usage; No Poe Pse Usage - Siemens SCALANCE XM-400 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Configuration
3.5 PoE
Further notes
You configure the value for the parameter "Maximum Power" with the
command.
3.5.2.3

poe pse usage

Description
With this command, you set a value (as a percentage) for the "Usage Threshold" parameter.
This specifies how many percent of the maximum power the connected devices will use. As
soon as the power being used by the end devices exceeds this percentage, an event is
triggered. An event is also entered in the log. You display the entries of the log with the
command
"show logbook (Page 762)".
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
poe pse usage <percent>
The parameters have the following meaning:
Parameter
percent
Result
The value for "Usage Threshold" is configured.
3.5.2.4

no poe pse usage

Description
With this command, you set the "Usage Threshold" parameter to the default value of 80%.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
122
. You will find more information on this command in the section
show logbook
Description
Value for "Usage Threshold" as a percentage.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
poe pse MaximumPower