Layer 3 functions
9.2 OSPFv2 (IPv4)
9.2.3.14

no default-information originate

Description
With this command, you disable the function with which a standard route is generated for
external routes into the OSPF routing domain.
Note
This command is available only with layer 3.
Requirement
You are in the OSPF Router configuration mode.
The command prompt is as follows:
cli(config-ospf)#
Syntax
Call up the command with the following parameters:
no default-information originate [(
[always]
[metric <metric-value (0-0xffffff)>]
[metric-type <type (1-2)>])]
The parameters have the following meaning:
Parameter
always
metric
metric-value
metric-type
type
Result
The function is disabled.
468
Description
The external standard route is always
generated.
Keyword for the metric of the external
standard route.
Value of the metric
Keyword for the type of the external
standard route
Type of the external route
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
--
0-0xffffff
--
1 - type 1
External and internal costs
2 - type 2
External costs
Configuration Manual, 11/2015, C79000-G8976-C252-10

Hide quick links: