Further notes
You enable the "disable" reaction with the
You can display the status of this function and other information with the show loopd
command.
12.3.3.5

loopd reaction remote

Description
With this command, you enable the "disable" reaction for a remote loop. If a remote loop is
detected, the port is blocked.
Requirement
● Loop detection is enabled.
● You are in the Interface configuration mode.
The command prompt is:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
loopd reaction remote
Result
"disable" is activated for the
"disable" is the default after enabling loop detection.
Further notes
You enable the "no action" reaction with the
You can display the status of this function and other information with the
command.
12.3.3.6

no loopd reaction remote

Description
With this command, you enable the "no action" reaction for a remote loop. If a remote loop is
detected, this has no effect on the port.
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
loopd reaction local
loopd reaction remote
no loopd reaction remote
12.3 Loop detection
command.
function.
command.
show loopd
Diagnostics
793