Siemens SCALANCE XM-400 Configuration Manual page 805

Industrial ethernet switches
Hide thumbs Also See for SCALANCE XM-400:
Table of Contents

Advertisement

Syntax
Call up the command for the port to be monitored with the following parameter assignment:
no monitor session<session-id(1-7)> source
{interface {<interface-type><interface-id> | port-channel <port-channel-id (1-8)>}
[{rx|tx|both}]}
or
Call up the command for the VLAN to be monitored with the following parameter assignment:
no monitor session <session-id (1-1)> source
{vlan <vlan-id> | mac-acl <acl-id>} | ip-acl <acl-id>}
The parameters have the following meaning:
Parameter
session-id
interface
interface-type
interface-id
port-channel
port-channel-id
rx
tx
both
vlan
vlan-id
mac-acl
ip-acl
acl-id
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
If you do not select any parameters from the parameter list, the default value (both) is used.
Result
The source for the mirroring of a port is deleted.
Further notes
You configure the source for mirroring a port with the
You end and delete a session with the
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Configuration Manual, 11/2015, C79000-G8976-C252-10
Description
Number of the session
7 parallel sessions are possible only
with port-based mirroring and their
ports must not overlap.
Keyword for a an interface description
Type or speed of the interface
Module no. and port no. of the interface
Keyword for a port channel connection
Number of the addressed port channel
Received data traffic will be mirrored
(received)
Transmitted data traffic will be mirrored
(transmitted)
Received and sent data traffic will be
mirrored
Keyword for a VLAN connection
Number of the VLAN
Keyword for a MAC access control list
Keyword for an IP access control list
Number of the Access Control List
no monitor session
12.4 Port Mirroring
Range of values / note
1 ... 7
-
Enter a valid interface.
-
1 ... 8
-
-
-
-
1 ... 4094
-
-
-
monitor session ... source
command.
Diagnostics
command.
805

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance xr-500

Table of Contents