Diagnostics
12.6 Syslog Client
Syntax
Call up the command with the following parameters:
no syslogserver { ipv4 <ucast_addr> | fqdn-name <FQDN> | ipv6 <ip6_addr>}
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
ipv6
ip6_addr
For information on names of addresses and interfaces, refer to the section "Interface
identifiers and addresses (Page 39)".
Result
The Syslog server is deleted.
Further notes
You add a Syslog server with the
820
Description
Keyword for an IPv4 address
IPv4 unicast address of the Syslog
server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name)
Keyword for an IPv6 address
IPv6 address of the Syslog server
syslogserver
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
-
Enter a valid IPv4 address.
-
Maximum of 100 characters
-
Enter a valid IPv6 address.
command.