Diagnostics
12.5 RMON
Syntax
Call up the command with the following parameters:
rmon collection history<index(1-52)>
[buckets<bucket-number(1-65535)>]
[interval<seconds(1-3600)>]
[owner<ownername(127)>]
The parameters have the following meaning:
Parameter
index
buckets
bucket-number
interval
seconds
owner
ownername
If you do not select any parameter from the parameter list, the default values are used.
Result
The data is recorded.
Further notes
You can display the content of a recording with the
12.5.3.4

no rmon collection history

Description
With this command, you end the recording of statistical data of the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
816
Description
Number of the recording
Maximum number of recording inter-
vals
Number of recording intervals
Duration of an individual recording
interval
Time in seconds
User to which the event is assigned
User name of the user
SCALANCE XM-400/XR-500 Command Line Interface (CLI)
Range of values / note
1 ... 65535
-
1 ... 65535
Default: 50
-
1 ... 3600
Default: 1800
-
max. 127 characters
Default: monitor
show rmon history