15.4 PLC Side Setting
YASKAWA PLC
1
Communication and port settings
Make the communication and port settings with a peripheral tool.
Device Name
*1
Address
Protocol
Mode
*2*3
Transmission speed
Data length
Stop bit
Parity bit
Error check
*1
Set the address according to the Host Address setting on the GOT side.
For the Host Address setting on the GOT side, refer to the following.
*2
Only transmission speeds available on the GOT side are shown.
Also, the setting range differs depending on the YASKAWA PLC model.
*3
Set the same transmission speed as that of the GOT side.
For the transmission speed setting on the GOT side, refer to the following.
For details of YASKAWA PLCs, refer to the following manuals.
Manuals for YASKAWA PLCs
Section 15.3.3 Setting communication interface (Communication settings)
Section 15.3.3 Setting communication interface (Communication settings)
Settings
1 to 31
MEMOBUS
RTU
4800bps, 9600bps, 19200bps, 38400bps, 57600bps
8 bits
1 bit
Even
CRC16
15.4 PLC Side Setting
15.3.7 Checking for normal monitoring
9
10
11
12
13
14
15
16
15 - 33