7.3 PLC Side Settings
This section describes the settings of the GOT and peripheral connection module in the case of the system
configuration shown as
1
System configuration
Switch settings of CC-Link module (Q Series)
[Network parameter] of GX Developer
*1
The CC-Link module is mounted on the base unit slot 0.
7 - 18
7.3 PLC Side Settings
.
(1) Peripheral connection module
For details of the peripheral connection module, refer to the following manual.
Peripheral Connection Module Type AJ65BT-G4-S3 User's Manual (detail
volume)
(2) CC-Link module (Q Series)
For details of the CC-Link module (Q Series), refer to the following manual.
CC-Link System Master/Local Module User's Manual QJ61BT11N
*1
<CC-Link module>
Station type
: Master station
Station No.
: Station No. 0
Mode
: Remote net (Ver.1 mode)
All connect count
: 1
: 156kbps
Transmission speed
Switch setting of peripheral connection module
The Start I/O No. of the CC-Link module is set to "0"
<AJ65BT-G4-S3>
Station type
Station No.
Number of stations occupied
Transmission speed
[Communication settings] of GT Designer 2
<GOT>
Transmisston speed: 9600bps
: Intelligent device station
: Station No. 1
: Exclusive station 1
: 156kbps