Mitsubishi GOT1000 Series Connection Manual page 337

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

(c) Settings of buffer memory used in the following example
Buffer memory
address
Dec (Hex)
0 to 1 (0 to 1
)
IP address of Ethernet module
H
16 (10
)
H
Application setting
24 (18
)
Port No. of Ethernet module
H
25 to 26 (19 to 1A
)
IP address of GOT
H
27 (1B
)
Port No. of GOT
H
80 (50
)
Initial fault code
H
*1
The details of the application setting are shown below.
Settings 1), 2) and 3) can be changed by the user.
4), 5) and 6) are fixed.
b15
b14
b13
b12
b11
b10
0
0
0
0
0
6)
1) Fixed buffer application
0: For sending; no exchange
1: For receiving
2) Existence check
0: No
1: Yes
3) Pairing open
0: No
1: Yes
4) Communication format (Set to "1" (UDP/IP).)
0: TCP/IP
1: UDP/IP
5) Fixed buffer exchange (Set to "0" (With procedure).)
0: With procedure
1: Without procedure
6) Open method (Set to "00" (Active, UDP/IP).
00: Active, UDP/IP
10: Unpassive
11: Fullpassive
Item
*1
b9
b8
b7
b6
b5
b4
b3
b2
0
0
1
0
0
0
0
0
5)
4)
3)
8.3.3 Connecting to Ethernet module (A Series)
C0A80013
b1
b0
0
0
0
2)
1)
8.3 PLC Side Setting
1
Setting
(192.168.0.19)
H
2
100
H
5001
FFFFFFFF
H
FFFF
(fixed)
H
-
3
4
5
6
7
8
8 - 33