6.3.2
Connecting to CC-Link module (QnA Series)
This section describes the settings of the GOT and CC-Link module (QnA Series) in the case of system
configuration shown as
CC-Link module (QnA Series)
1
System configuration
<CC-Link module>
*1
Station type
Station No.
Mode setting
All connect count
Transmisson speed
Switch settings of CC-Link module (QnA Series)
Parameter setting
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0"
.
For details of the CC-Link module (QnA Series), refer to the following manual.
Control & Communication Link System Master/Local Module Type
AJ61QBT11/A1SJ61QBT11 User's Manual
[Communication settings] of GT Designer2
Setting of the CC-Link communication unit
(Use the default value for settings other than the following.)
: Master staton
: Station No.0
: Remote net mode
: 1
: 156kbps
6.3.2 Connecting to CC-Link module (QnA Series)
<GOT> (Use the default value for settings other than the following.)
Station type
Station No.
Number of stations occupied
Transmission speed
6.3 PLC Side Setting
: Intelligent device station
: Station No.1
: Exclusive station 1
: 156kbps
6 - 25