Mitsubishi GOT1000 Series Connection Manual page 222

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

2
Switch setting of MELSECNET/10 network module
Set for each setting switch.
AJ71QLP21
A
J71QLP21
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
1
DUAL -
- D.LINK
SW.E -
- T.PASS
M/S.E -
-
100
PRM.E -
- CPUR/W
CRC -
- CRC
OVER -
- OVER
E
E
AB.IF -
- AB.IF
R
R
TIME -
- TIME
R
R
DATA -
- DATA
O
UNDER -
- UNDER
O
LOOP -
- LOOP
R
R
SD -
- SD
RD -
- RD
F.LOOP
R.LOOP
NETWORK NO.
X100
X10
X1
GROUP NO.
STATION NO.
X10
X1
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
3
PRM
D.PRM
4
STATION SIZE
(8.16.32.64)
5
6
LB/LW SIZE
(2.4.6.8K)
7
8
FRONT SIDE
IN
OUT
A1SJ71QLP21
A1SJ71QLP21
RUN
CRC
PW
‚d
MNG
PC
OVER
‚q
S.MNG
AB. IF
REM.
‚q
DUAL
SWE.
TIME
‚n
D.LINK
DATA
‚q
M/S.E.
T.PASS
PRM E.
UNDER
F.E.
SD
R.E.
CPU R/W
RD
NETWORK
NO.
DISPLAY
X100
L
R
(F.L)
(R.L.)
(1)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
8
(3)
X1
OFF ON
SW
C
1
(5)
MODE
2
3
MODE
4
0 : ONLINE(A.R)
5
2 : OFFLINE
6
FRONT SIDE
7
8
IN
OUT
A1SJ71QLP21
5 - 30
5.3 PLC Side Setting
5.3.2 Connecting to MELSECNET/10 network module (QnA Series)
AJ71QLP21S
A
J71QLP21S
RUN -
PC -
REMOTE -
10
DUAL -
SW.E -
M/S.E -
100
PRM.E -
CRC -
OVER -
E
AB.IF -
R
TIME -
R
DATA -
O
UNDER -
LOOP -
R
SD -
RD -
F.LOOP
NETWORK NO.
(1)
(2)
GROUP NO.
STATION NO.
(3)
(5)
0: ONLINE(A.R)
2: OFFLINE
OFF
PC
REMOTE
N.ST
PRM
(6)
STATION SIZE
(8.16.32.64)
LB/LW SIZE
(2.4.6.8K)
24V
24G
FG
FRONT SIDE
OUT
A1SJ71QLP21S
A1SJ71QLP21S
EXT.P W
(4)
(1)
(2)
(3)
EXT.PW
{24V
24G
(6)
FG
(5)
A1SJ71QLP21S
- POWER
- MNG
- S.MNG
1
- D.LINK
- T.PASS
- EX.POWER
- CPUR/W
- CRC
- OVER
E
- AB.IF
R
- TIME
R
- DATA
- UNDER
O
- LOOP
R
- SD
- RD
R.LOOP
X100
(1)
X10
X1
(2)
X10
(3)
X1
MODE
(5)
OFF
ON SW
ON
1
MNG
2
D.PRM
3
(6)
4
5
6
7
8
IN
PW
RUN
CRC
‚d
PC
MNG
OVER
‚q
REM.
S.MNG
AB. IF
‚q
SWE.
DUAL
TIME
‚n
D.LINK
M/S.E.
DATA
‚q
PRM E.
T.PASS
UNDER
F.E.
R.E.
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
X100
L
R
(F.L)
(R.L.)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
8
X1
OFF ON
SW
C
1
MODE
2
3
MODE
4
0 : ONLINE(A.R)
5
2 : FOFFLINE
6
FRONT SIDE
7
8
IN
OUT
AJ71QBR11
A
J71QBR11
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
1
- D.LINK
SW.E -
- T.PASS
M/S.E -
-
100
PRM.E -
- CPUR/W
CRC -
OVER -
E
AB.IF -
R
TIME -
R
DATA -
O
UNDER -
R
SD -
RD -
NETWORK NO.
X100
X10
X1
GROUP NO.
STATION NO.
X10
X1
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
PRM
D.PRM
3
STATION SIZE
4
(8.16.32.64)
5
LB/LW SIZE
6
(2.4.6.8K)
7
8
A1SJ71QBR11
A1SJ71QBR11
RUN
PW
MNG
PC
S.MNG
REM.
SWE.
D.LINK
M/S.E.
T.PASS
PRM E.
CPU R/W
NETWORK
NO.
DISPLAY
(4)
X100
L
(F.L)
(1)
X10
X1
SW
OFF
1
2
N.ST
(2)
3
PRM
GR.NO.
4
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
8
(3)
X1
OFF ON
C
(5)
MODE
MODE
(6)
0 : ONLINE (A.R)
2 : OFFLINE
A1SJ71QBR11
(1)
(2)
(3)
(5)
(6)
CRC
‚d
OVER
‚q
AB. IF
‚q
TIME
‚n
DATA
‚q
UNDER
SD
RD
R
(4)
(R.L.)
ON
PC
REM.
MNG
D.PRM
ST,SIZE
2,4,6,8k
SW
1
2
3
4
(6)
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents