Mitsubishi GOT1000 Series Connection Manual page 762

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

(b) When reading a bit device
The following shows an example of reading the two points of the virtual devices M0 to M31.
(Assuming M0="1" and M31="1" are stored.)
Item
Request message
(host
GOT)
Response
message during
normal
communication
(GOT
host)
(format 1: GOT-A900 series microcomputer connection (format 1))
Response
message during
(format 2: GOT-A900 series microcomputer connection (format 2))
faulty
communication
(GOT
host)
19 - 32
19.5 Message Formats
19.5.3 Formats 1, 2 (GOT-A900 series microcomputer connection)
M15 to 0
M31 to 16
Message format
STX
Command
Address
R
D
8
3
02
52
44
38
33
32
H
H
H
H
H
(H)
(L)
(H)
Sum check is performed in this range.
Sum check is performed in this range.
STX
Data 1 (M15 to 0)
0
0
0
1
02
30
30
30
31
38
H
H
H
H
H
(H)
(L)
(H)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
1
1
1
1
1
1
9
8
7
6
5
4
3
2
1
0
3
3
5
4
3
2
1
0
1
0
Error
NAK
code
15
06
H
The above is a case where
the sum check error (06
has occurred.
0001
H
8000
H
Number of
ETX
points
Check
2
0
0
2
C
30
30
32
03
43
H
H
H
H
H
(L)
(H)
(L)
(H)
Data 2 (M31 to 16)
ETX
Check
8
0
0
0
8
30
30
30
03
38
H
H
H
H
H
(L)
(H)
0
0
0
0
0
0
0
0
0
0
0
0
0
0
M
M
M
M
M
M
M
M
M
M
M
M
M
M
2
2
2
2
2
2
2
2
2
2
1
1
1
1
9
8
7
6
5
4
3
2
1
0
9
8
7
6
NAK
15
H
H
)
H
Sum
8
38
H
H
(L)
Sum
C
43
H
H
(L)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents