Mitsubishi GOT1000 Series Connection Manual page 1016

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

2
Communication detail settings
Item
Transmission Speed
Data Bit
Stop Bit
Parity
25 - 8
25.2 Preparatory Procedures for Monitoring
25.2.3 Setting communication interface (Communication settings)
Set this item when change the transmission speed used for
communication with the connected equipment.
<Default: 9600bps>
Set this item when change the data length used for
communication with the connected equipment.
<Default: 8bit>
Specify the stop bit length for communications.
<Default: 1bit>
Specify whether or not to perform a parity check, and how it
is performed during communication.
<Default: Even>
(1) Communication interface setting by Utility
The communication interface setting can be changed on the Utility's
"Communication setting" after downloading "Communication setting" of project
data.
For details on the Utility, refer to the following manual.
GT
User's Manual
(2) Precedence in communication settings
When settings are made by GT Designer or the Utility, the latest setting is
effective.
Description
Range
4800bps, 9600bps,
19200bps, 38400bps,
57600bps, 115200bps
7bit/8bit
1bit/2bit
None
Even
Odd