22.4 Temperature Controller Side Setting
Temperature controller
22.4.1 Connecting to H-PCP-J
1
Communication settings
Make the communication settings of the temperature controller.
Setting item
*1
Transmission speed
Communication mode
Data length
Parity bit
Stop bit
*2
Unit address
*1
Make the same setting as that of the GOT side.
*2
Select the unit address without overlapping with that of other units.
2
Settings by DIP switch
Make the settings of transmission speed, communication mode, data length, parity bit and stop bit.
COM.PORT3
COM.PORT1
COM.PORT2
22 - 32
22.4 Temperature Controller Side Setting
22.4.1 Connecting to H-PCP-J
RKC temperature controller
For details of RKC temperature controller, refer to the following manual.
User's Manual for the RKC temperature controller
Model name
H-PCP-J
H-PCP-A, H-PCP-B
9600bps, 19200bps, 38400bps
MODBUS
8bits
None
1bit
0 to F
Front
Setting range
Right side
Reference
Section 22.4.1
Section 22.4.2
COM.PORT1/COM.PORT2
setting switch(SW2)
COM.PORT3setting switch
(SW3)

Hide quick links: