Mitsubishi GOT1000 Series Connection Manual page 204

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

3
Switch setting
For details of each setting switch and LED, refer to the following manual.
(1) Network number setting switch
Network number setting
switch
5
X100
5
X10
5
X1
(2) Group number setting switch
Group number setting switch
5
GROUP No.
*1
The GOT does not use the group number.
Specify "0".
(3) Station number setting switch
Station number setting switch
5
STATION
No.
5
5 - 12
5.2 Preparatory Procedures for Monitoring
5.2.3 Setting communication interface (Communication settings)
GT15 MELSECNET/10 communication unit User's Manual
GT15-75J71LP23-Z, GT15-75J71BR13-Z
RUN
POWER
PC
D.LINK
DUAL
SW.E
T.PASS
M/S.E
E
E
PRM.E
GOT R/W
R
R
CRC
CRC
R
R
OVER
OVER
O
O
AB.IF
AB.IF
R
R
TIME
TIME
DATA
DATA
UNDER
UNDER
LOOP
LOOP
SD
SD
RD
RD
F.LOOP
R.LOOP
5
8
5
(4)
MODE
5
5
X10
(3)
STATION
No.
5
5
X1
Set the network No. of the MELSECNET/10 communication unit.
NETWORK
<Default: 001>
No.
Set the group No. of the MELSECNET/10 communication unit.
<Default: 0>
X10
Set the station No. of the MELSECNET/10 communication unit.
Set to not duplicate other stations in the network.
<Default: 01>
X1
(2)
GROUP No.
X100
(1)
NETWORK
X10
No.
X1
Description
Description
Description
Setting
1 to 239
Setting
*1
0: No group setting (fixed)
Setting
1 to 64: GT15-75J71LP23-Z
1 to 32: GT15-75J71BR13-Z