(b) Coaxial cable connector connection method
The following describes the method for connecting the BCN connector (connector plug for
coaxial cable) and the cable.
• Solder the coaxial cable connectors properly.
Insufficient soldering may result in malfunctions.
Components of the BNC connector
Plug shell
4
15mm
Cut this portion of the outer sheath
Clamp
Washer
Gasket
Insulating material
Internal conductor
3mm
6mm
Clamp and external
conductor
Solder here
CAUTION
Nut
Washer
Gasket
Clamp
Contact
1
Remove the external sheath of the coaxial cable
with dimensions as shown on the left.
2
Pass the nut, washer, gasket, and clamp through the
coaxial cable as shown on the left and loosen the
external conductor.
Nut
3
Cut the external conductor, insulting material, and
internal conductor with the dimensions as shown on
the left.
Note that the external conductor should be cut to the
same dimension as the tapered section of the clamp
and smoothed down to the clamp.
4
Solder the contact to the internal conductor.
5.2 Preparatory Procedures for Monitoring
5.2.5 Attaching communication unit and connecting cable
Structure of the coaxial cable
External conductor
Outer sheath
Insulating material
Internal conductor
1
2
3
4
5
6
7
8