This manual contains text, diagrams and explanations which will guide the reader in the correct
installation, safe use and operation of the F930GOT-BBD-K-E and should be read and understood before
attempting to install or use the unit. Further information can be found in the associated manuals list below.
Specifications are subject to change without notice
Guidelines for the Safety of the User and Protection of the
F930GOT-BBD-K-E
This manual has been written to be used by trained and competent personnel. The definition of such a
person or persons is as follows:
a) Any engineer using the product associated with this manual, should be of a competent nature,
trained and qualified to the local and national standards. These engineers should be fully aware of
all aspects of safety with regards to automated equipment.
b) Any commissioning or service engineer must be of a competent nature, trained and qualified to
the local and national standards.
c) All operators of the completed equipment should be trained to use that product in a safe and
co-ordinated manner in compliance to established safety practices.
Note: The term 'completed equipment' refers to a third party constructed device which contains or uses
the product associated with this manual.
Note's on the Symbols Used in this Manual
At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the users personal safety and protect the integrity of equipment.
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and property
damage.
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples.
Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application.
Associated Manuals
Manual Name
GOT-F900 Series
!
Operation Manual
GOT-F900 Series
!
Hardware Manual
(connection diagram)
FX-PCS-DU/WIN-E
"
SOFTWARE MANUAL
SW*D5C-GOTR-PACKE
"
Operating Manual
! Indispensable manual
" Either manual is necessary.
Refer to the manual of the connected programmable controller for details concerning that unit.
Manual Number
This manual contains explanations for the
JY992D94701
operation and use of the GOT-F900 series
graphic operation terminals.
This manual contains explanations for the
JY992D94801
wiring and installation, etc. of the GOT-F900
series graphic operation terminals.
This manual contains explanations for the
JY992D68301
operation of FX-PCS-DU/WIN-E screen design
software.
This manual contains explanations for the
-
operation of GT-Designer (SW*D5C-GOTR-
PACKE) screen design software.
F930GOT-BBD-K-E
Installation Manual
JY997D02501B
Description

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi F930GOT-BBD-K-E

  • Page 1 This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the F930GOT-BBD-K-E and should be read and understood before attempting to install or use the unit. Further information can be found in the associated manuals list below.
  • Page 2: Product Lists

    1. Introduction The F930GOT-BBD-K-E (hereafter called “GOT”) is to be mounted on the face of a control panel or operations panel, and connected to the programming port (CPU port) or the communication port (communication units port) of a PLC. Various devices can be monitored and PLC data changed through...
  • Page 3: General Specifications

    1.2 Dimensions and Each Part Name Dimensions: mm (inches) Mass (Weight): 0.6 kg (1.32 lbs) Accessory: Mounting brackets, Tightening bolt (M3, 4 bolts), Packing seal for dust and water resistance a) Display Front panel 168(6.61") b) LED (green) c) Function keys d) Cursor keys e) 0 to 9 keys Mounting bracket and tightening...
  • Page 4: Installation

    2.3 Screen Hardware Specifications Items Specifications Display Device STN monochrome liquid crystal 240 × 80 (dot), 30 characters × 5 lines Resolution 0.47 mm (0.019") Horizontal × 0.47 mm (0.019") Vertical. Dot Pitch Effective Display 117 mm (4.61") × 42 mm (1.65"); 4 (4.4 inch) type Size Number of Colors 2 colors (White and Blue)
  • Page 5: Wiring For Power Supply

    Note: Make sure to tighten the clamping bolts with a torque of 0.3 ~ 0.5 N# # # # m. 4) Peeling of protective sheet Make sure to peel off the protective sheet on the surface of the product before use. Dimensions required inside 20(0.79") 37.5(1.48")
  • Page 6: Maintenance

    C2(0.08") 3(0.12") Unit: mm Manual number : JY997D02501 Manual revision : B Date : July 2002 HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...
  • Page 7 GOT-F900 Series Hardware g) Communication ports installation, safe use and operation of the F930GOT-BBD-K-E and should be read and understood before Manual. attempting to install or use the unit. Further information can be found in the associated manuals list below.
  • Page 8 Mounting bracket 6.2 mm (0.24" ) or less φ 3.2 (0.13") Terminal Terminal 6.2 mm (0.24") or less HEAD OFFICE : MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310 TELEX : J24532 CABLE MELCO TOKYO HIMEJI WORKS : 840, CHIYODA CHO, HIMEJI, JAPAN...

This manual is also suitable for:

Got-f900

Table of Contents