Mitsubishi GOT1000 Series Connection Manual page 760

Graphic operation terminal
Hide thumbs Also See for GOT1000 Series:
Table of Contents

Advertisement

(6) Data
Specifies data to read from/write to the specified device data. (word unit)
Data notated in Hex is converted to a 4-digit ASCII code (Hex) and transmitted from the upper digit.
(7) Error code
This is the response message at faulty communication appended with error contents.
Error code is transmitted in 1 byte.
For details of the error codes generated in format 2 (GOT-A900 series microcomputer connection
(format 2)), refer to the following:
(8) Sum check code
The sum check code is obtained by converting the lower 1 byte (8 bits) of the result (sum), after
having added the sum check target data as binary data, to 2-digit ASCII code (Hex).
19 - 30
19.5 Message Formats
19.5.3 Formats 1, 2 (GOT-A900 series microcomputer connection)
Error code list
STX
Command
Address
R
D
0
1
02
52
44
30
31
H
H
H
H
H
(H)
(L)
(H)
Sum check is performed in this range.
52
+ 44
+ 30
+ 31
+ 30
H
H
H
H
Number of
ETX
points
0
0
0
2
30
30
30
32
03
H
H
H
H
H
(L)
(H)
(L)
+ 30
+ 30
+ 32
+ 03
= 1BC
H
H
H
H
H
H
Sum
Check
B
C
42
43
H
H
(H)
(L)