21.4.6 Station NO. settings

Set each station number while making sure that one station number is used only once.
The station number can be set without regard to the cable connection order. No problem is expected even if
station numbers are not consecutive.
GOT
(1) Direct specification
When setting the device, specify the station number of the temperature controller of which data is
to be changed.
SDC40A/40B/40G, SDC15, SDC25/26,
SDC35/36, SDC20/21, SDC30/31
DMC10
(2) Indirect specification
When setting the device, indirectly specify the station number of the inverter of which data is to be
changed using the 16-bit GOT internal data register (GD10 to GD 25 ).
When specifying the station No. from 200 to 215 on GT Designer2, the value of GD10 to GD25
compatible to the station No. specification will be the station No. of the temperature controller.
Specification station NO.
(3) All station specification
Target station differs depending on write-in operation or read-out operation.
• For write-in operation, all station will be a target.
• For read-out operation, only one station will be a target.
21 - 42
21.4 Temperature Controller Side Setting
21.4.6 Station NO. settings
Station No.3
Station No.0
Examples of station number setting
Model
Compatible device
200
GD10
201
GD11
202
GD12
203
GD13
204
GD14
205
GD15
206
GD16
207
GD17
208
GD18
209
GD19
210
GD20
211
GD21
212
GD22
213
GD23
214
GD24
215
GD25
Station No.1 Station No.15 Station No.6
Specification range
0 to 127
0 to 15
0 to 127 : For SDC40A/40B/40G, SDC15, SDC25/26,
SDC35/36, SDC20/21, SDC30/31
0 to 15
: For DMC10
For the setting other than the above, a communication timeout error
will occur.
Setting range