POWER INPUT LINE INSPECTION
Measure the voltage between the Yellow/red wire
terminal (+) of the wire harness side connector and
ground (–).
Turn the ignition switch ON.
There should be approx. 5 V.
GROUND LINE INSPECTION
Check for continuity between the Green/orange wire
terminal of the wire harness side connector and
ground.
There should be continuity at all times.
SIGNAL LINE INSPECTION
Measure the voltage between the Pink wire terminal
(+) of the wire harness side connector and ground (–
).
Turn the ignition switch ON.
There should be approx. 5 V.
Turn the ignition switch OFF.
Disconnect the ECM 33P (Gray) connector.
Check the Orange/blue wire for continuity between
the immobilizer receiver and ECM connectors.
There should be continuity.
Check for continuity between the Orange/blue wire
terminal and ground.
There should be no continuity.
TOOL:
Test probe
Connect the ECM 33P (Gray) connector.
4P (NATURAL) CONNECTOR
(Wire side/male terminal)
4P (NATURAL) CONNECTOR
(Wire side/male terminal)
2P (NATURAL) CONNECTOR
(Wire side/female terminal)
O/Bu
07ZAJ-RDJA110
IMMOBILIZER SYSTEM (HISS)
Y/R
G/O
P
4P (NATURAL) CONNECTOR
(Wire side/male terminal)
B32
33P (GRAY) CONNECTOR
(Wire side/female terminal)