Acura Integra 1998 Service Manual page 1343

Integra 1998
Hide thumbs Also See for Integra 1998:
Table of Contents

Advertisement

)
Erasing the DTC Memory
To erase the DTC(S) from the SRS unit, use a Honda
P G M t e s t e r ( s e e t h e H o n d a P G M T e s t e r S R S v e h i c l e
System Supplement) or the following procedure.
1. Make sure the ignition switch is OFF.
2.
Connect the SCS service connector to the MES con-
nector (2P). Do not use a jumper wlre.
MEMORY EMSE
SIGNAL {MESI CONNESTOR I2P)
[GRN, GBNI or IWHT, BLKI
Turn the ignition switch ON (ll).
The SBS indicator light comes on for about six sec-
onds and goes off. Remove the SCS service connec-
tor from the MES connector (2P) within four seconds
after the SRS indicator light went off.
The SRS indicator light comes on again. Reconnect
the scs service connector to the MES connector
(2P) within the four seconds after the SRS indicator
light comes on.
The SRS indicator light goes off. Remove the SCS
s e r v i c e c o n n e c t o r f r o m t h e M E S c o n n e c t o r ( 2 P )
within four seconds.
The SRS indicator light indicates that the memory is
erased by blinking two times.
Turn the ignition switch OFF. and wait for ten sec-
onos.
Troubleshootin g Intermittent
Failures
lf the.e was a malfunction, but it doesn't recur, it will be
stored in the memory as an intermittent failure, and the
SRS indicator light comes on,
Atter chocking ths DTC, troubleshoot as follows:
1. Read the DTC (see
"Reading the DTC").
2 . E r a s e t h e D T C m e m o r y ( s e e
" E r a s i n g t h e D T C
Memory").
3.
With the shift l€ver in neutral, turn the ignition switch
ON (ll), and let the engine idle.
4. The SRS indicator light comes on for about six sec-
onds and then goes off.
I o"* 1--
ON
l
l
I
Shake the wire harness and the connector, take a test
drive (quick acceleration, quick braking, cornering),
and turn the steering wheel fully left and righi, and
hold I there for fve to ten s€conds lo 6nd tt|e caus€
of the intermnem farlure
It lhe problem .!curs, lha SRS nd'calor r'ghl will
$aY on.
,l soc or less
Problem recurs, Iight stays on
lf vou can't duplicate the intermittent failure, the sys-
tem is OK at this time.
SRS indic.lol
light
MES
connaclot
tarrninlll
CONNECTED
DISCONNECTED
23-289